SPD TrigeTron T1 H 1+0, code 6825112-70
GTIN:
6825112-80
,
Product code:
6825112-70
,
Customs tariff No.:,
Gross weight: ,
PU:
1.00
Certificates




Related products
Protection type EN / IEC 61643-11 Τ1 (Class I)
Number of poles 4
Connection between terminals L1–N, L2–N, L3–N & N–PE
Installation in TN S, TN CS, TT
Nominal operating voltage, Un 230/400 V, 50 Hz
Maximum operating voltage, Uc 300 V (L–N) / 305 V (N–PE), 50 Hz
Ιimp, “class I” test, (10/350μs), 1P 25 kA (L–N) / 100 kA (N–PE)
Ιmax, “class II” test, (8/20μs), 1P 65 kA (L–N) / 130 kA (N–PE)
Ιn, “class II” test, (8/20μs), 1P 25 kA (L–N) / 100 kA (N–PE)
Up, (at In) <1,5 kV (L–N) / <1,5 kV (N–PE)
Responce time, ta <25 ns (L–N) / <100 ns (N–PE)
Maximum back up fuse <315 A gG
Short circuit withstand, Ιsccr 50 kA / 50 Hz
Follow current interrupt rating (N–PE), Ifi 100 A rms
Temporary overvoltage (TOV) 120min L-N 442 V withstand
Temporary overvoltage (TOV) 200ms N-PE 1200 V withstand
Thermal protection & monitoring indication YES
Residual current, IPE <5 μA
Installation location indoor
Protection level of housing ΙΡ20 (built in)
Dimensions WxHxD (mm) 144x106x87 mm
Operating temperature -40 oC ÷ +80 oC
Relative humidity 5% ÷ 95%
Rail mounting DIN-3 (TS-35/EN50022)
Housing material Polycarbonate halogen free
Maximum conductor for terminal 35 mm2
Conductor terminals tightening torque 2,5 Nm
Maximum conductor for remote contacts 1,5 mm2
Combined equivalent protection as per TS 61643–12 & IEC 61643-12 T1 (CAT IV) + T2 (CAT III & CAT II) + T3 CAT I)
Certification VDE, CE
Conformity with LVD 2014/35/EU
Installation only by qualified electrician IEC 60417–6182
ELEMKO management systems ISO 9001, ISO 14001, ISO 45001
SPD TrigeTron T1 HS 100, code 6825425-70
GTIN:
6825425-80
,
Product code:
6825425-70
,
Customs tariff No.:,
Gross weight:
427.00
,
PU:
1.00
Certificates




Additional Information
-
Tender Budgetary Pricelist
-
Unit Price: 1470.00€
-
Installation Price: 400.00€
-
Related products
SPD TrigeTron T1 HS 100, code 6825425-70
GTIN:
6825425-80
,
Product code:
6825425-70
,
Customs tariff No.:,
Gross weight:
427.00
,
PU:
1.00
Protection type EN / IEC 61643-11 Τ1 (Class I)
Number of poles 4
Connection between terminals L1–N, L2–N, L3–N & N–PE
Installation in TN S, TN CS, TT
Nominal operating voltage, Un 230/400 V, 50 Hz
Maximum operating voltage, Uc 300 V (L–N) / 305 V (N–PE), 50 Hz
Ιimp, “class I” test, (10/350μs), 1P 12,5 kA (L–N) / 50 kA (N–PE)
Ιmax, “class II” test, (8/20μs), 1P 65 kA (L–N) / 100 kA (N–PE)
Ιn, “class II” test, (8/20μs), 1P 20 kA (L–N) / 50 kA (N–PE)
Up, (at In) <1,5 kV (L–N) / <1,5 kV (N–PE)
Responce time, ta <25 ns (L–N) / <100 ns (N–PE)
Maximum back up fuse <315 A gG
Short circuit withstand, Ιsccr 25 kA / 50 Hz
Follow current interrupt rating (N–PE), Ifi 100 A rms
Temporary overvoltage (TOV) 120min L-N 442 V withstand
Temporary overvoltage (TOV) 200ms N-PE 1200 V withstand
Thermal protection & monitoring indication YES
Residual current, IPE <5 μA
Installation location indoor
Protection level of housing ΙΡ20 (built in)
Dimensions WxHxD (mm) 72x106x87 mm
Operating temperature -40 oC ÷ +80 oC
Relative humidity 5% ÷ 95%
Rail mounting DIN-3 (TS-35/EN50022)
Housing material Polycarbonate halogen free
Maximum conductor for terminal 35 mm2
Conductor terminals tightening torque 2,5 Nm
Maximum conductor for remote contacts 1,5 mm2
Combined equivalent protection as per TS 61643–12 & IEC 61643-12 T1 (CAT IV) + T2 (CAT III & CAT II) + T3 CAT I)
Certification VDE, CE
Conformity with LVD 2014/35/EU
Installation only by qualified electrician IEC 60417–6182
ELEMKO management systems ISO 9001, ISO 14001, ISO 45001
SPD TrigeTron T1 H 50, code 6825412-70
GTIN:
6825412-80
,
Product code:
6825412-70
,
Customs tariff No.:,
Gross weight: ,
PU:
1.00
Certificates




Related products
SPD TrigeTron T1 H 50, code 6825412-70
GTIN:
6825412-80
,
Product code:
6825412-70
,
Customs tariff No.:,
Gross weight: ,
PU:
1.00
Protection type EN / IEC 61643-11 Τ1 (Class I)
Number of poles 1
Connection between terminals N-PE
Installation in TN S, TN CS, TT
Nominal operating voltage, Un 230/400 V, 50 Hz
Maximum operating voltage, Uc 305 V, 50 Hz
Ιimp, “class I” test, (10/350μs), 1P 50 kA
Ιmax, “class II” test, (8/20μs), 1P 100 kA
Ιn, “class II” test, (8/20μs), 1P 50 kA
Up, (at In) <1,5 kV
Responce time, ta <100 ns
Follow current interrupt rating, Ifi 100 A rms
Temporary overvoltage (TOV) 200ms N-PE 1200 V withstand
Thermal protection & monitoring indication YES
Residual current, IPE <5 μA
Installation location indoor
Protection level of housing ΙΡ20 (built in)
Dimensions WxHxD (mm) 17,5x106x87 mm
Operating temperature -40 oC ÷ +80 oC
Relative humidity 5% ÷ 95%
Rail mounting DIN-3 (TS-35/EN50022)
Housing material Polycarbonate halogen free
Maximum conductor for terminal 35 mm2
Conductor terminals tightening torque 2,5 Nm
Maximum conductor for remote contacts 1,5 mm2
Combined equivalent protection as per TS 61643–12 & IEC 61643-12 T1 (CAT IV) + T2 (CAT III & CAT II) + T3 CAT I)
Certification VDE, CE
Conformity with LVD 2014/35/EU
Installation only by qualified electrician IEC 60417–6182
ELEMKO management systems ISO 9001, ISO 14001, ISO 45001
SPD TrigeTron T1 H NPE 0+1, code 6825050-70
GTIN:
6825050-80
,
Product code:
6825050-70
,
Customs tariff No.:,
Gross weight: ,
PU:
1.00
Certificates




Related products
SPD TrigeTron T1 H NPE 0+1, code 6825050-70
GTIN:
6825050-80
,
Product code:
6825050-70
,
Customs tariff No.:,
Gross weight: ,
PU:
1.00